13 CONFIGURATIONS · ONE PRODUCT PLATFORM
Start with one or two connectors
Choose a single-connector or dual-connector record, then compare its listed power. The complete cabinet illustration retains the original blue equipment base, grey display, wrapped guns and cables.
Compare all 13 floor-standing options
The fixed dual-cabinet image does not become a separate photograph of every option when you change the selection. Confirm the actual connector interface and selected electrical version with its documentation.

Compare the 13 order configurations
Three records list one connector at 20, 30 or 40kW. Ten list two connectors at 60, 80, 120, 160, 180, 240, 280, 320, 360 or 400kW. All list floor-standing mounting and a 5m cable.
13 configurations
No matching configuration. Reset the filters to view all records.
| Option | Listed power | Cable length | Connector arrangement | Mounting | Combined mounting / connector label | Select a version |
|---|---|---|---|---|---|---|
| DC52-01 | 20kW | 5m | Single connector | Floor-standing | Floor-standing · Single connector | |
| DC52-02 | 30kW | 5m | Single connector | Floor-standing | Floor-standing · Single connector | |
| DC52-03 | 40kW | 5m | Single connector | Floor-standing | Floor-standing · Single connector | |
| DC52-04 | 60kW | 5m | Dual connector | Floor-standing | Floor-standing · Dual connector | |
| DC52-05 | 80kW | 5m | Dual connector | Floor-standing | Floor-standing · Dual connector | |
| DC52-06 | 120kW | 5m | Dual connector | Floor-standing | Floor-standing · Dual connector | |
| DC52-07 | 160kW | 5m | Dual connector | Floor-standing | Floor-standing · Dual connector | |
| DC52-08 | 180kW | 5m | Dual connector | Floor-standing | Floor-standing · Dual connector | |
| DC52-09 | 240kW | 5m | Dual connector | Floor-standing | Floor-standing · Dual connector | |
| DC52-10 | 280kW | 5m | Dual connector | Floor-standing | Floor-standing · Dual connector | |
| DC52-11 | 320kW | 5m | Dual connector | Floor-standing | Floor-standing · Dual connector | |
| DC52-12 | 360kW | 5m | Dual connector | Floor-standing | Floor-standing · Dual connector | |
| DC52-13 | 400kW | 5m | Dual connector | Floor-standing | Floor-standing · Dual connector |
Read the illustrated 120KW unit’s specifications
The complete 22-row illustration is shown together with readable page text. These are the printed specifications of the illustrated 120KW unit, not engineering ratings automatically assigned to all 13 order records.
| Interaction methods | Card, QR code, password, VIN code, etc. |
|---|---|
| Design standards | GB/T 18487 GB/T 20234 |
| AC input voltage | 380V AC±20% |
| Input frequency | 50HZ±10% |
| Standby power | ≤24W |
| Rated power | 120KW |
| Output voltage range | DC150-1000V |
| Maximum output current | 250A |
| Efficiency | ≥95% |
| Power factor | ≥0.99 (at 50% load and above) |
| Safety design | Overcurrent/overvoltage, undervoltage/undercurrent, leakage, short circuit, lightning, connector-temperature, high-temperature, low-temperature, emergency-stop, access-control, insulation-monitoring and earthing protection. |
| Network connection | 4G / Ethernet |
| Installation environment | Indoors / outdoors |
| Installation altitude | <2000M |
| Operating temperature | -20°C~+50°C |
| Storage temperature | -40°C~+70°C |
| Operating temperature (second printed row) | 5%-95% non-condensing |
| Protection rating | IP54 IP55 |
| Cooling method | Air cooling |
| Product dimensions | 1650*680*380MM |
| Material | Sheet iron |
| Charging cable length | 5m |
Dimensions are measured manually; deviations may occur.

Keep the selected version and its documents together
The illustration prints 120KW, 250A, AC380V±20% input and DC150-1000V output. The individual comparison above carries five stated configuration fields; request the matching electrical sheet for the selected option.
The original sheet repeats “Operating temperature” for the row containing 5%-95% non-condensing. Both the repeated source label and its percentage value are retained, rather than changing the original into an assumed corrected specification.
Other product-level electrical fields separately state DC750V and place an AC380V three-phase entry with a 15% marking in a field named output-voltage range. They have not been merged into the illustration’s supply and output values. A shared -30~50°C entry and 3W standby entry also remain separate from the illustrated -20°C~+50°C and ≤24W.
The source prints both IP54 and IP55 without mapping them to individual configurations. The GB/T numbers are source design-standard text, not a certificate. Discuss the matching protection documents, network hardware and local services for the selected version.
Request a clearly identified floor-standing version
- Choose the listed power and one or two connectors.
- Identify the actual vehicle inlet and site electrical supply.
- Request the matching electrical sheet, installation drawing and cable route.
- Agree the operating instructions, sample contents and packing list.
Changing the optional selection updates editable request notes only. It does not establish compatibility, accessories, certification or a new product snapshot.
No configuration selected.